QXEDGP Series

Thermoplastic Edge-lit Exit

QXEDGP Series Thermoplastic Edge-lit Exit Sign

Equity Line

Equity Line
QXEDGP Series Thermoplastic Edge-lit Exit Sign is from our Equity Line of products.

More Equity Line Products


QXEDGP Series Thermoplastic Edge-lit Exit Sign

The Exitronix QXEDGP edge-lit exit sign features elegant styling in an economical LED thermoplastic design. It features simple installation with field-selectable chevrons that have a factory-installed guide template for multiple directional configurations. A snap-in canopy is included for simple top, end or surface mount installations. Single-face signs include an ultra-clear acrylic panel while double-face signs utilize a factory-installed mirror-finish mylar insert between two clear acrylic panels.

cULus Listed Damp Locations CEC Compliant Warranty

Features & Benefits

  • UV-stabilized, ultra-clear, acrylic edge-lit panel provides consistent, uniform illumination
  • Field-selectable chevrons with self-adhesive appliques and guide template provided
  • Suitable for Damp Locations
  • Suitable for ceiling, end or wall mount
  • California Energy Commission (CEC) Title 20 Compliant
CONSTRUCTION
The QXEDGP has an injection-molded enclosure constructed of UV stabilized, UL 94 5VA flame-retardant, high-temperature, high-impact thermoplastic. UV-stabilized ultra-clear acrylic edge-lit panel provides consistent, uniform illumination. Fixtures resist denting, peeling, scratching and corrosion. NFPA approved field-selectable chevrons.
ILLUMINATION
Fully illuminated 6" letters with 3/4" stroke is achieved with high-output, long-lasting LEDs. Single-face legends come standard with clear acrylic panel. Double-face legends come standard with mirror insert between the clear acrylic panels.
ELECTRICAL

Input
Dual-voltage input 120 or 277VAC @ 60Hz.

Nickel Cadmium Battery – NiCad
Exitronix nickel cadmium batteries are maintenance free.

Emergency
The QXEDGP Series exit will operate for a minimum of 90 minutes during a loss of power with a 24 hour maximum recharge time for the battery.

Solid-State Transfer
The circuit features solid-state switching for emergency lighting, eliminating concerns of damaged contact or mechanical failures associated with relays. The switching circuit detects a loss of line voltage and automatically switches to emergency mode. Unique bi-color LED indicator light alerts occupant on battery condition (Green-normal, Red-check battery).

Test Button
The test button is easy to locate and provides manual verification of the transfer circuit.

Damp Location Rated
Damp Location Rated fixture that is normally or periodically subject to condensation of moisture in, on or adjacent to, and includes partially protected locations.

INSTALLATION

Mounting canopy is supplied with all signs and snaps into enclosure with< two (2) positive locking tabs.

OPTIONS

Guardian Self-Test/Self-Diagnostics (Option: G2)
The Guardian circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit.

The purpose of this option is to provide visual signaling in response to a fault at the EXIT sign battery and/or battery charger. If a failure is detected, visual status will occur immediately via the CHARGER LED and/or the BATTERY FAULT LED. The LED will stay illuminated until the fault is corrected.

The Guardian circuit also monitors the transfer circuit as well as performing automatic code-compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 30 days. A 60 minute discharge and self-test is performed every 6 months, and a 90 minute discharge and self test is performed every 12 months.

CONFORMANCE TO CODES & STANDARDS

The QXEDGP Series is UL 924 Listed for Damp Locations and meets or exceeds the following: CEC, NEC requirements and NFPA 101.


QXEDGP Series Thermoplastic Edge-lit Exit Sign

IES Files



Contact us or your sales rep if you need a part number that isn't listed here.

QXEDGP-D-GM-WB-WH
QXEDGP-D-GM-WB-WH-G2
QXEDGP-D-RM-WB-WH
QXEDGP-D-RM-WB-WH-G2
QXEDGP-S-GC-WB-WH
QXEDGP-S-GC-WB-WH-G2
QXEDGP-S-GM-WB-WH
QXEDGP-S-GM-WB-WH-G2
QXEDGP-S-RC-WB-WH
QXEDGP-S-RC-WB-WH-G2
QXEDGP-S-RM-WB-WH
QXEDGP-S-RM-WB-WH-G2

Enter your zip code to find a representative in your area.


exitronix trace lite specialty led growlite
Equity Line


Thermoplastic Edge-lit Exit

The Exitronix QXEDGP edge-lit exit sign features elegant styling in an economical LED thermoplastic design. It features simple installation with field-selectable chevrons that have a factory-installed guide template for multiple directional configurations. A snap-in canopy is included for simple top, end or surface mount installations. Single-face signs include an ultra-clear acrylic panel while double-face signs utilize a factory-installed mirror-finish mylar insert between two clear acrylic panels.

cULus Listed Damp Locations CEC Compliant Warranty

Need more information?

We are happy to answer any questions you have about the QXEDGP Series Thermoplastic Edge-lit Exit Sign.

Spec Sheet Request More Info

Configure your QXEDGP Series Thermoplastic Edge-lit Exit Sign

Series
Number of Faces
Legend Color
Power Source
Finish
Options

Configure your QXEDGP Series Thermoplastic Edge-lit Exit Sign

Series
Number of Faces
Legend Color
Power Source
Finish
Options

Features & Benefits

  • UV-stabilized, ultra-clear, acrylic edge-lit panel provides consistent, uniform illumination
  • Field-selectable chevrons with self-adhesive appliques and guide template provided
  • Suitable for Damp Locations
  • Suitable for ceiling, end or wall mount
  • California Energy Commission (CEC) Title 20 Compliant
CONSTRUCTION
The QXEDGP has an injection-molded enclosure constructed of UV stabilized, UL 94 5VA flame-retardant, high-temperature, high-impact thermoplastic. UV-stabilized ultra-clear acrylic edge-lit panel provides consistent, uniform illumination. Fixtures resist denting, peeling, scratching and corrosion. NFPA approved field-selectable chevrons.
ILLUMINATION
Fully illuminated 6" letters with 3/4" stroke is achieved with high-output, long-lasting LEDs. Single-face legends come standard with clear acrylic panel. Double-face legends come standard with mirror insert between the clear acrylic panels.
ELECTRICAL

Input
Dual-voltage input 120 or 277VAC @ 60Hz.

Nickel Cadmium Battery – NiCad
Exitronix nickel cadmium batteries are maintenance free.

Emergency
The QXEDGP Series exit will operate for a minimum of 90 minutes during a loss of power with a 24 hour maximum recharge time for the battery.

Solid-State Transfer
The circuit features solid-state switching for emergency lighting, eliminating concerns of damaged contact or mechanical failures associated with relays. The switching circuit detects a loss of line voltage and automatically switches to emergency mode. Unique bi-color LED indicator light alerts occupant on battery condition (Green-normal, Red-check battery).

Test Button
The test button is easy to locate and provides manual verification of the transfer circuit.

Damp Location Rated
Damp Location Rated fixture that is normally or periodically subject to condensation of moisture in, on or adjacent to, and includes partially protected locations.

INSTALLATION

Mounting canopy is supplied with all signs and snaps into enclosure with< two (2) positive locking tabs.

OPTIONS

Guardian Self-Test/Self-Diagnostics (Option: G2)
The Guardian circuit continuously monitors the operating condition of the AC power, battery supply voltage, emergency lamp continuity and charging circuit.

The purpose of this option is to provide visual signaling in response to a fault at the EXIT sign battery and/or battery charger. If a failure is detected, visual status will occur immediately via the CHARGER LED and/or the BATTERY FAULT LED. The LED will stay illuminated until the fault is corrected.

The Guardian circuit also monitors the transfer circuit as well as performing automatic code-compliant testing. The Guardian circuit will perform a 30 second discharge and self-test every 30 days. A 60 minute discharge and self-test is performed every 6 months, and a 90 minute discharge and self test is performed every 12 months.

CONFORMANCE TO CODES & STANDARDS

The QXEDGP Series is UL 924 Listed for Damp Locations and meets or exceeds the following: CEC, NEC requirements and NFPA 101.


Contact us or your sales rep if you need a part number that isn't listed here.

QXEDGP-D-GM-WB-WH
QXEDGP-D-GM-WB-WH-G2
QXEDGP-D-RM-WB-WH
QXEDGP-D-RM-WB-WH-G2
QXEDGP-S-GC-WB-WH
QXEDGP-S-GC-WB-WH-G2
QXEDGP-S-GM-WB-WH
QXEDGP-S-GM-WB-WH-G2
QXEDGP-S-RC-WB-WH
QXEDGP-S-RC-WB-WH-G2
QXEDGP-S-RM-WB-WH
QXEDGP-S-RM-WB-WH-G2

Enter your zip code to find a representative in your area.


We Have More ItemsYou may also like